VIL Lucas Hybrid Inverters combine German technology with advanced energy management for unmatched performance.
They deliver maximum efficiency, ensuring optimal use of both solar and grid power.
Equipped with Multi Power Point Tracking (MPPT), they capture the highest possible energy from your solar panels.
With pure sine wave output, your appliances and equipment run smoothly and safely.
The intelligent battery management system (BMS) optimizes charging and extends battery life.
Compatible with Lithium, GEL, and Tubular batteries, they offer complete flexibility for every installation.
Built for quiet, reliable, and long-lasting operation, VIL Lucas Hybrid Inverters keep your power uninterrupted.
FEATURES OF THE VIL LUCAS INVERTERS
Pure sine wave output for stable performance
Intelligent battery management system (BMS)
LCD for real-time monitoring
Multi Power Point Tracking (MPPT)
Overload and short circuit protection
Compatible with Lithium, GEL, and Tubular batteries
Remote monitoring
12 months warranty
MODEL | VIL-UC2524AMX | VIL-UC3524AMX | VIL-UC5024AMX | VIL-UC5048AMX | VIL-UC10048AMX |
---|---|---|---|---|---|
INPUT | |||||
Capacity (VA) | 2500VA | 3500VA | 5000VA | 5000VA | 10000VA |
Voltage (DC) | 24V | 24V | 24V | 48V | 48V |
Nominal Voltage | 220VAC/110VAC | ||||
Voltage Range | 154-265VAC/77-135VAC | ||||
Frequency | 50-60HZ Auto Sensing | ||||
Output | |||||
Watt | 1600W | 2400W | 4000W | 5000W | 8000W |
Voltage | 220VAC/110VAC (± 10 % ups mode) | ||||
Frequency | 50/60HZ | ||||
Waveform | Pure Sinewave | ||||
Transfer time (AC to DC) | <8ms | ||||
Transfer time (DC to AC) | <8ms | ||||
Output Voltage Regulation | 10%rms | ||||
Bypass Mode | Yes | ||||
Saver Mode | Yes | ||||
Efficiency | >98% | ||||
Protection | |||||
Input Protection | Circuit Breaker | ||||
Output Protection | Circuit Breaker | ||||
Battery | |||||
Battery Type | AGM-Deep Cycle, GEL,LIFEPO4 | ||||
Up to 500Ah | |||||
Charging Current | 35/18A | 30/15A | 20A | 40A | 60A |
Low Level disconnect (selectable) | 24V: (20V or 21V) 48V:(40V or 42V) | ||||
LCD Indicator Status | Input AC, Output AC | ||||
Battery DC, Output Load | |||||
Alarm Fault | |||||
Battery Charge Level | |||||
Output Frequency | |||||
LED Indicator status | AC Line In: Green | ||||
Inverter: Green | |||||
Charging:Yellow | |||||
Alarm:Red | |||||
Battery Low Alarm | 24V: Battery light discharge 23V; battery load discharge 23V @load<20%; 22V@load>50%/21V @load>50% 48V: Battery light discharge 46V; battery load discharge46V @load<20%; 44V@load>50%/42V @load>50% | ||||
Battery Low Recovery | 24V: Battery light discharge 24V; battery load discharge 24V @load<20%; 23V@load>50%/22V @load>50% 48V: Battery light discharge 48V; battery load discharge48V @load<20%; 44V@load>50%/44V @load>50% | ||||
DC low voltage Shutdown | 24V: Battery light discharge 22V; battery load discharge 22V @load<20%; 22V@load>50%/20V @load>50% 48V: Battery light discharge 44V; battery load discharge44V @load<20%; 42V@load>50%/40V @load>50% | ||||
DC High Voltage Alarm and Fault | 31.2V/62.4V | 62.4V | |||
DC high Voltage Recovery | 30V/60V | 60V | |||
Maximum PV array Power | 24V: 1600W 48:3200W | 48:6400W | |||
MPPT input voltage range | 24V:MPPT 30-150VDC 48:MPPT 60-150VDC | 48:MPPT 60-150VDC | |||
Maximum PV array open circuit voltage | 24V:MPPT 150VDC 48:MPPT 150VDC | 48:MPPT 150VDC | |||
Maximum Solar Charging Current | 60A | 120A | |||
Alarm | |||||
Low Battery Alarm | Audible Alarm-1beeping per second | ||||
Overload Alarm | Audible Alarm-continous Beeping | ||||
Fault | Audible alarm-continous beeping | ||||
Environment | |||||
Temperature | -10 ~ 50ºC | ||||
Humidity | C0-95%, Non Condensing | ||||
Accoustic Noise (dB) | <45dB | ||||
Standards and certifications | EN-IEC 60335-1, EN-IEC 60335-2-29, IEC 62109-1 |