VIL Lucas 2.5kVA ~ 10kVA (24V/48V) NON-HYBRID Low Frequency Inverter
VIL Lucas 2.5kVA ~ 10kVA (24V/48V) NON-HYBRID Low Frequency Inverter   thumbnail 1
VIL Lucas 2.5kVA ~ 10kVA (24V/48V) NON-HYBRID Low Frequency Inverter   thumbnail 2
VIL Lucas 2.5kVA ~ 10kVA (24V/48V) NON-HYBRID Low Frequency Inverter   thumbnail 3

VIL Lucas 2.5kVA ~ 10kVA (24V/48V) NON-HYBRID Low Frequency Inverter

VIL Lucas Non-Hybrid Inverters are crafted with precision German technology for exceptional performance.
They deliver maximum efficiency, ensuring every watt of power is utilized effectively.
Designed for extremely low noise operation, they fit seamlessly into any environment.
With a pure sine wave output, your appliances and equipment run at their optimal performance.
The intelligent battery management system (BMS) safeguards and extends battery life.
Compatible with Lithium, GEL, and Tubular batteries, they offer complete flexibility.
Built for enduring reliability, VIL Lucas Inverters are the power solution you can depend on.

FEATURES OF THE VIL LUCAS INVERTERS

  • Pure sine wave output for stable performance

  • Intelligent battery management system (BMS)

  • LCD for real-time monitoring

  • Overload and short circuit protection

  • Compatible with Lithium, GEL, and Tubular batteries

  • Remote monitoring

  • 12 months warranty

MODELVIL-UC2524AXVIL-UC3524AXVIL-UC5024AX
VIL-UC5048AX
VIL-UC10048AX
INPUT
Capacity (VA)2500VA3500VA5000VA5000VA10000VA
Voltage (DC)24V24V24V48V48V
Nominal Voltage220VAC/110VAC
Voltage Range154-265VAC/77-135VAC
Frequency50-60HZ Auto Sensing
Output
Watt1600W2400W4000W5000W8000W
Voltage220VAC/110VAC (± 10 % ups mode)
Frequency50/60HZ
WaveformPure Sinewave
Transfer time (AC to DC)<8ms
Transfer time (DC to AC)<8ms
Output Voltage Regulation10%rms
Bypass ModeYes
Saver ModeYes
Efficiency>98%
Protection
Input ProtectionCircuit Breaker
Output ProtectionCircuit Breaker
Battery
Battery TypeAGM-Deep Cycle, GEL,LIFEPO4
Up to 500Ah
Charging Current35/18A30/15A20A40A60A
Low Level disconnect (selectable)

24V: (20V or 21V)

48V:(40V or 42V)

LCD Indicator StatusInput AC, Output AC
Battery DC, Output Load
Alarm Fault
Battery Charge Level
Output Frequency
LED Indicator statusAC Line In: Green
Inverter: Green
Charging:Yellow
Alarm:Red
Battery Low Alarm

24V: Battery light discharge 23V; battery load discharge 23V @load<20%;

22V@load>50%/21V @load>50%

48V: Battery light discharge 46V; battery load discharge46V @load<20%;

44V@load>50%/42V @load>50%

Battery Low Recovery

24V: Battery light discharge 24V; battery load discharge 24V @load<20%;

23V@load>50%/22V @load>50%

48V: Battery light discharge 48V; battery load discharge48V @load<20%;

44V@load>50%/44V @load>50%

DC low voltage Shutdown

24V: Battery light discharge 22V; battery load discharge 22V @load<20%;

22V@load>50%/20V @load>50%

48V: Battery light discharge 44V; battery load discharge44V @load<20%;

42V@load>50%/40V @load>50%

DC High Voltage Alarm and Fault31.2V/62.4V62.4V
DC high Voltage Recovery30V/60V60V
Alarm
Low Battery AlarmAudible Alarm-1beeping per second
Overload AlarmAudible Alarm-continous Beeping
FaultAudible alarm-continous beeping
Environment
Temperature-10 ~ 50ºC
HumidityC0-95%, Non Condensing
Accoustic Noise (dB)<45dB
Standards and certificationsEN-IEC   60335-1, EN-IEC 60335-2-29, IEC 62109-1
Note: Due to a unified manufacturing design, some non-hybrid inverters may have "Hybrid" printed on the casing. We apply product-specific labeling to ensure each unit is correctly identified. This does not affect functionality or performance.